SOLAIO IN ACCIAIO
interasse (m)
|
qs (KN/m2)
|
qp (KN/m2)
|
qa (KN/m2)
|
q (KN/m)
|
luce (m)
|
M (KN*m)
|
fy,k (N/mm2)
|
sigam (N/mm2)
|
Wx (cm3)
|
1
|
1,15
|
3,02
|
2,00
|
6,17
|
3,35
|
8,655353
|
275
|
239,13
|
36,20
|
Dimensionamento trave
interasse (m)
|
qs (KN/m2)
|
qp (KN/m2)
|
qa (KN/m2)
|
q (KN/m)
|
luce (m)
|
M (KN*m)
|
fy,k (N/mm2)
|
sigam (N/mm2)
|
Wx (cm3)
|
3,35
|
1,25
|
3,02
|
2,00
|
21,0045
|
6,7
|
117,8615
|
275
|
239,13
|
492,88
|
interasse (m)
|
qs (KN/m2)
|
qp (KN/m2)
|
qa (KN/m2)
|
q (KN/m)
|
luce (m)
|
M (KN*m)
|
fy,k (N/mm2)
|
sigam (N/mm2)
|
Wx (cm3)
|
3,35
|
1,37
|
3,02
|
2,00
|
21,4065
|
6,7
|
120,1172
|
275
|
239,13
|
502,31
|
interasse (m)
|
qs (KN/m2)
|
qp (KN/m2)
|
qa (KN/m2)
|
q (KN/m)
|
luce (m)
|
M (KN*m)
|
fm,k (N/mm2)
|
kmod
|
sigam (N/mm2)
|
b (cm)
|
h (cm)
|
1
|
0,18
|
3,57
|
2,00
|
5,75
|
3,35
|
8,066172
|
24
|
0,6
|
9,93
|
14
|
18,66
|
interasse (m)
|
qs (KN/m2)
|
qp (KN/m2)
|
qa (KN/m2)
|
q (KN/m)
|
luce (m)
|
M (KN*m)
|
fm,k (N/mm2)
|
kmod
|
sigam (N/mm2)
|
b (cm)
|
h (cm)
|
3,35
|
0,28
|
3,57
|
2,00
|
19,5975
|
6,7
|
109,9665
|
28
|
0,6
|
11,59
|
30
|
43,57
|
interasse (m)
|
qs (KN/m2)
|
qp (KN/m2)
|
qa (KN/m2)
|
q (KN/m)
|
luce (m)
|
M (KN*m)
|
fm,k (N/mm2)
|
kmod
|
sigam (N/mm2)
|
b (cm)
|
h (cm)
|
3,35
|
0,44
|
3,57
|
2,00
|
20,1335
|
6,7
|
112,9741
|
28
|
0,6
|
11,59
|
30
|
44,16
|
Ottengo un’altezza h=44,16 cm < h=45 cm --> VERIFICATO
SOLAIO IN CLS
Scelgo un un pacchetto di solaio in laterocemento con travetti armati.
Inserisco i valori all’interno del foglio excel assumendo come tipo di cls C35/45 (Rck=45 N/mmq) e per le barre un acciaio B450C.
interasse (m)
|
qs (KN/m2)
|
qp (KN/m2)
|
qa (KN/m2)
|
q (KN/m)
|
luce (m)
|
M (KN*m)
|
fy (N/mm2)
|
sig_fa (N/mm2)
|
Rck (N/mm2)
|
3,35
|
2,36
|
3,07
|
2,00
|
24,8905
|
6,7
|
139,6668
|
450
|
391,30
|
45
|
sig_ca (N/mm2)
|
alfa
|
r
|
b (cm)
|
h (cm)
|
delta (cm)
|
H (cm)
|
H/l
|
area (m2)
|
peso (KN/m)
|
25,50
|
0,49
|
2,20
|
30
|
29,74
|
5
|
34,74
|
0,052
|
0,10
|
2,61
|
interasse (m)
|
qs (KN/m2)
|
qp (KN/m2)
|
qa (KN/m2)
|
q (KN/m)
|
luce (m)
|
M (KN*m)
|
fy (N/mm2)
|
sig_fa (N/mm2)
|
Rck (N/mm2)
|
3,35
|
3,13
|
3,07
|
2,00
|
27,47
|
6,7
|
154,141
|
450
|
391,30
|
45
|
sig_ca (N/mm2)
|
alfa
|
r
|
b (cm)
|
h (cm)
|
delta (cm)
|
H (cm)
|
H/l
|
area (m2)
|
peso (KN/m)
|
25,50
|
0,49
|
2,20
|
30
|
31,24
|
5
|
36,24
|
0,054
|
0,11
|
2,72
|
H=36,24 cm < 40 cm --> VERIFICATO